Dual Precision Analytical Electronic Balance


Specifications:


  • ​ Four Level Anti-Shock Adjustable Function

  •  Super Size LCD display with backlight Pan Size: ¢90

  •  Dual Weighing Range/Weighing Precision

  •  Weighing Response time Adjustable

  •  Default and auto lock present working mode

  •  17 Units Available ,ct,lb,oz,ozt,GN,dwt...

  •  Built in RS232/USB for printer or other equipment

  •  Counting And Weighing

  •  Time & Date Setting 

  • Dynamic Weighing , % , Density Weighing…

  •  Built in Under hook 

  • Display present temperature

  •  Numeric Linearity Calibration

  •  Electro Magnetic Base

  •  Anti-Static Metal Windproof Back Board

  •  Humanity Tool Box for put weight mass and RS232 Cable Warm Up Time: 60-120minutes



Different models of this product is available
Please file Enquiry for different model according to your requirement.

INVERTED MICROSCOPE RIC-551D


Specifications:


  • ​​​ Pixel:  5 Mega Photo Resolution 2560X1920-1600X1200 Video

  • Resolution : 640X480 Sensor

  • Size : 1/2.5 Inches

  • LCD: Screen 8 Inches TFT Screen, Resolution is 800X 600

  • Video Output AV Output (NTSC/PAL)

  • Data Output USB2.0 Storage SD Card Slot with Optional Memory Cards (Maximal Storage Capacity is 4G)

  • Scene Mode:  Standard / Softness / Vivid Digital Parts

  • Exposure Mode:  Auto Exposure

  • Viewing Head Compensation Free Binocular Head, Inclined at 30°, Interpupillary Distance 48 -75mm

  • Eyepiece High-point, Extra Wide Field Eyepiece EW10×/ 22 LWD Infinite Plan

  • Objective 4×/ 0.1,WD 18mm 40×/ 0.6,WD 2.6mm PH10×/ 0.25,WD 10 mm Objective Infinite Plan Phase Objective PH20×/ 0.4,WD 5.1mm

  • Nosepiece Quintuple Nosepiece

  • Filter Diameter 45mm, Blue, Green and Ground Glass

  • Illumination Halogen Lamp 6V/ 30W

  • Condenser ELWD Condenser NA 0.3, LWD 72mm (Without Condenser 150mm)

  • Annulus 10×-20×、40× Phase Annulus

  • Plate Plain Stage 160×250mm, Glass Insert Stage Auxiliary Stages 70×180mm

  • Focusing Coaxial Coarse and Fine Adjustment, Vertical Objective Movement;Coarse Stroke 37.7mm per Rotation, Fine Stroke 0.2mm per Rotation

  • Illumination Halogen Lamp 6V/ 30W Optical Parts

  • Filter Diameter 45mm, Blue、Green and Ground Glass LWD Infinite Plan

  • Objective 10×/ 0.25, WD 10mm 20×/ 0.4, WD 5.1mm Objective Infinite Plan Phase Objective PH40×/ 0.65, WD 0.35mm

  • Centering Centering Telescope (Φ30MM)

  • Phase Annulus 10×-20×、40× Phase Annulus Plate Attachable Mechanical

  • Stage, X-Y Coaxial Control,Moving Rang 120×78mm Optional Parts Stage Φ38mm Petri Dish Holder

ULTRA SONICATORS RIC-760 SERIES


Specifications:


  • As a new type of ultrasonic homogenizer,it enjoys complete functions, novel appearance and reliable performance.

  • It has a large-screen display and concentrated control by a central computer.

  • The ultrasonic time and power can be set accordingly. Besides, such functions as sample temperature display, actual frequency display, computerized tracking and automatic trouble warning can all be displayed in the large LCD screen


ModelFrequency (kHz)
power (W)
Tip Diameter Options
Standard

Crushing

(ml) 

RIC-760A
202501/8" 1/4"
1/8"
0.5~200
RIC-760B
205001/8" 1/4" 3/8" 
1/4"
0.5~300
RIC-760C
207501/8" 1/4" 1/2" 
1/2"
0.5~600
RIC-760D
209001/4" 1/2" 9/16" 
1/2"
20~700
RIC-760E
201200 1/4"1/2" 9/16" 3/4"
3/4"
20~1000
RIC-760F
2015001/4" 1/2"9/16"3/4"1" 
3/4"
20~1200
RIC-760G
2018001/2"9/16"3/4"1" 
1"
100~1200


XRF SPECTROMETERS


Specifications:


  • ​Outstanding sensitivity leads to up to a factor 3 improved precision- 
    the basis for high accuracy when analyzing minor to major element concentrations

  • Measure lower than ever: Adaptive excitation, advanced tube design and high-count throughput detection system result in significantly (typically a factor 3) lower limits of detection for a wide range of elements

  •  Master the unknown: The Turboquant II software tool provides an unprecedented ability to analyze unknown samples, regardless if they are liquid, solid or powder - whether tree leaves, plastics, oil, granite or glass

​A Solution Provider Company

AUTOCLAVE (HORIZONTAL)

RIC-34CH


Specifications:


  • ​​​Chamber, Constructed from S.S 304 Grade

  •  Lid Closing by Radial Locking System  

  • Sealing of lid by Neoprene Rubber Gasket

  •  Chamber Insulated by Mineral/Glass Wool

  •  Over Pressure Safety by safety Valve.  

  • Continuous Monitoring of Pressure ! Water level Indicator

  •  Sterilizing Temperature upto 134˚C

  •  Sterilizing Pressure up to 2.1kg/cm2

  •  Tested up to 2.5 times of required pressure Voltage: 220Volts AC (50hz)


Different models of this product is available

      Please file Enquiry for different model         according to your requirement.


DOUBLE BEAM UV-VIS SPECTRO PHOT OMETER RIC-73E-B-L SERIES VARIABLE BANDWIDTH


Specifications:


  • Model RIC-73E-V-B-L

  • Light Path Double Beam

  • Spectral Bandwidth nm 0.5& 1 & 2 & 4

  • Screen 7” TFT Colour Screen

  • Stray Light =0.03 %T

  • Wavelength Range 190 to 1100nm

  • Wavelength Accuracy ±0.3 nm

  • Wavelength Repeatability 0.1nm

  • Transmittance Accuracy ±0.3%T

  • Transmittance Repeatability ±0.1%T

  • Base Line Flatness ±0.0008Abs

  • Base Line Drift 0.0005Abs/H Noise ±0.00004Abs/H

  • Detector Photomultiplier

  • Software/ Workstation Available 




aTOMIC ABSORPTION SPECTROPHOTOMETER DOUBLE BEAM (FLAME MODEL)RIC-118


Specifications:


  • ​​Wavelength Range: 190-900nm

  • Wavelength Accuracy: ±0.25nm

  • Resolution: Two Spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%

  • Baseline Stability: ≤0.004A/30min.

  • Background correction: The D2 lamp background correction capability at 1A is better than 30 times.


Light Source:
  • Lamp turrel: 4-lamp turret

Auto-alignment, fully automated scan and peak-picking

  • Lamp current adjustment: Automatic adjustment and display.

                Wide pulse current: 0~25mA Narrow pulse current: 0~10mA Lamp power

  • supply mode: 400Hz square wave pulse

Ultra Centrifuge


Specifications:


  • ​Model : VS-65K

  • Max. 65,000RPM & 361,351 x g

  • Rotor auto recognition ㆍeasy to check

  • Display of real speed on LED.

  • setting content on LCD

  • Available 5 steps program depends on use purpose

  • Chamber Pre-conditioning

  • Carious Titanium Rotor

  • Safety device

  • Changeable Voltage(100V~240V,50Hz or 60Hz)

  • Certificate ISO9001, ISO-13485,ISO14001 

HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) , RIC-171-173


Specifications:


  • ​ RIC-171 to173 HPLC has modular design with maximum accuracy & reproducibility.

  • Up to 9000PSI operational pressure.

  • Higer working pressure extends the dynamic range in the application of chromatographic analysis, and improves the durability and reliability of the entire system.

  • Up to 2.5 AU linear range of the detector, allows accurate analysis for widely varying sample concentrations, either with high concentrated substance(s) or trace component(s).

  • Up to 100Hz data sampling rate, allows sharper peak(s) detection and enables ultra fast analysis.

  • Proprietary automatic solvent-compressibility compensation and pulsation dampening technologies enable excellent analysis reproducibility.

  • As low as 5x10-9 g/mL detection limit, creating higher sensitivity with lower noise floor.

  • Proprietary pump design and precision fabrication process result in excellent system durability.



Call Today: +91.9818047375

HANDHELD XRF ANALYZERS

Specifications:


  • Robust tool, analyzes most alloys in 2 seconds, and identifies alloys containing light elements in 7 seconds, standard calibration captures alloys and precious metals for 16 matrices with 46 elements 

  • Instrument usually ready to measure within 10 seconds after switching on, offers simultaneous result storage in various formats at different destinations (USB drive, network, or printer) 

  • Compliance testing and quick screening of non-metallic samples. Video-camera for exact sample positioning and documentation of measured spot. 



ICP-OES spectrometers


Specifications:


  • ​New revolutionary Dual Side-On Interface (DSOI) technology that achieves twice the sensitivity of conventional radial-plasma-view instruments 

  • Tl technology enables highest sensitivity for trace elements, as well as freedom from matrix interferences plus good accuracy for challenging environmental matrices

  • New GigE readout system that enables spectra transport in less than 100 ms for faster analysis speeds, shorter sample-to-sample times, and more samples per hour

  • Extremely agile, LDMOS generator that makes external cooling unnecessary: analyze difficult sample matrices in lower dilutions for lower limits of detection faster warmup (~10 minutes) for higher productivity